M and M Mountain View Subdivision Em2 water quality
Met every federal limit. 2 contaminants at half a limit or higher. hardness not in the latest CCR.
ID3140067. Data through 2026-08-19. DEQ record.
What's in it
Uranium
ElevatedAquasana OptimH2O Reverse Osmosis + Claryum: manufacturer-reported, not certified.
Nitrate (as N)
ElevatedEPA: infants below the age of six months who drink water containing nitrate in excess of the MCL could become seriously ill and, if untreated, may die.
Aquasana OptimH2O Reverse Osmosis + Claryum is certified to reduce it.
4 other contaminants tested, not detected or well below the limit
Gross Alpha 40.6pCi/L HFPO-DA (GenX) ND PFHxS ND Radium 226 + 228 ND
Filters that match
Aquasana OptimH2O Reverse Osmosis + Claryum
under sink ro · diy
- Nitrate (as N)removes it, NSF or WQA certified
- Uraniumremoves it, per manufacturer testing
Nothing in this water calls for whole-house treatment. A drinking-water filter covers the exposure that matters. Whole-house units here are optional, mainly for taste and chlorine.
Detections ranked by share of the limitevery Tier 1 detection, highest first
Bar length is the highest result in the last 36 months as a share of the federal limit (MCL, or action level for lead and copper). The dark tick marks the limit. Gross alpha is compared after subtracting uranium, as DEQ does for compliance.
Full contaminants reporthighest, latest, limit, trend, last sample
| Contaminant | Highest, 36 mo | Federal limit | Share of limit | Status | Trend | Last sample |
|---|---|---|---|---|---|---|
| Gross Alphanote | 40.6pCi/L latest 20.1pCi/L | 15.0pCi/L MCL | Detected | 2026-08-06 | ||
| HFPO-DA (GenX) | ND | 10.0ppt MCL | Not detected | 2026-03-17 | ||
| Nitrate (as N) | 5.50ppm latest 5.10ppm | 10.00ppm MCL | Elevated | 2026-08-19 | ||
| PFHxS | ND | 10.0ppt MCL | Not detected | 2026-03-17 | ||
| Radium 226 + 228 | ND | 5.00pCi/L MCL | Not detected | 2024-06-05 | ||
| Uranium | 27.0ppb latest 20.0ppb | 30.0ppb MCL | Elevated | 2026-08-19 |
- Gross Alpha: Compliance uses the running average of gross alpha minus uranium. Shown value is the highest lab result; the adjusted average is 5.83 pCi/L after subtracting 14.96 pCi/L for uranium.
ppb = parts per billion (µg/L), ppm = parts per million (mg/L), ppt = parts per trillion. ND = not detected above the lab's reporting limit. MCL = federal maximum contaminant level; AL = action level for lead and copper (90th percentile of home taps); aesthetic = secondary standard for taste, odor or staining, not health. Bars show the highest result in 36 months as a share of the limit.
4 other regulated contaminants tested
| Contaminant | 36 mo max | Limit | Status | Last sample |
|---|---|---|---|---|
| Atrazine | ND | 3.0ppb | Not detected | 2024-08-15 |
| 1,2-Dibromo-3-chloropropane | ND | 0.2ppb | Not detected | 2024-08-15 |
| Nitrite (as N) | ND | 1.00ppm | Not detected | 2026-05-13 |
| Sodium | 60.40ppm | none | Detected | 2024-03-04 |
Hardness
Hardness is not reported in the latest CCR. Hardness not reported for this system; softener sizing uses a regional default of 11.7 gpg until a CCR value is reviewed.
Track recordno violations in the last ten years
✓ no violation recorded n monitoring or reporting only n includes a health-based violation ? outside the loaded record
Lead and copper at the tap90th percentile of sampled homes against the action level
No lead and copper tap sampling summary in the window we reviewed.
Where the water comes from1 active wells
1 active well, and 0 treatment points on record (SDWIS counts each chlorination or filtration point as a treatment plant).
WELL #1A (NEW WELL 1): Susceptibility: ioc high (auto), voc moderate, soc moderate, microbial high (auto).
Source water assessment susceptibility: final map[IOC:Auto High Microbials:Auto High SOC:Moderate VOC:Moderate]; hydrologic sensitivity M; pci land use map[IOC:H Microbials:M SOC:M VOC:M]; system construction M;
Source names (1)
WELL #1A (NEW WELL 1)
Every match, by categorytop three per category
We may earn a commission if you buy through these links. Rankings come from the matching engine (certification + flagged contaminants + annual cost), not from who pays more. How we earn money. As an Amazon Associate we earn from qualifying purchases. Prices are not shown; Amazon sets them on its site.
Drinking water
Under sink, pitcher, or faucet. Treats the water you drink and cook with.
Aquasana OptimH2O Reverse Osmosis + Claryum
Certified for the elevated nitrate flag (NSF/ANSI 58); manufacturer-reported for uranium and gross alpha.
Plumber recommended if you are not comfortable with a drain saddle and a tank. Not a whole-house solution.
APEC ROES-50 Essence 5-Stage Reverse Osmosis
Manufacturer-reported reduction for uranium, nitrate, and gross alpha. Not NSF-certified for uranium, nitrate, and gross alpha.
Plumber recommended if you are not comfortable with a drain saddle and a tank. Not a whole-house solution.
Express Water RO5DX 5-Stage Reverse Osmosis System (50 GPD)
Manufacturer-reported reduction for uranium and nitrate. Not NSF-certified for uranium and nitrate.
Plumber recommended if you are not comfortable with a drain saddle and a tank. Not a whole-house solution.
Whole house
Installed where water enters the house. For fixtures, laundry and showers.
Nothing in this water calls for whole-house treatment. A drinking-water filter covers the exposure that matters. Whole-house units here are optional, mainly for taste and chlorine.
Sprite High Output 2 Universal Shower Filter with 3-Setting Shower Head (HO2-WH-M)
Does not address uranium and nitrate.
DIY. No plumbing.
Culligan WSH-C125 Wall-Mount Shower Filter
Does not address uranium and nitrate.
DIY. No plumbing.
Culligan ISH-100 Inline Shower Filter
Does not address uranium and nitrate.
DIY. No plumbing.
Softener or conditioner
Worth it at 7 grains per gallon or more.
Aquasure Serene Lite 650K Salt-Free Water Conditioner with Triple Purpose Pre-Filter
Does not address uranium and nitrate.
Plumber recommended if you are not comfortable with this install.
Whirlpool WHES30E 30,000 Grain Water Softener
Does not address uranium and nitrate.
DIY if you are comfortable with this install.
Whirlpool WHES40E 40,000 Grain Water Softener
Does not address uranium and nitrate.
DIY if you are comfortable with this install.
Questions about M and M Mountain View Subdivision Em2
Is M and M Mountain View Subdivision Em2 tap water safe to drink?
M and M Mountain View Subdivision Em2 met every federal limit in the last 36 months, with no open health-based violation. 2 contaminants were at half the limit or higher: Nitrate (as N) and Uranium. The results table shows each value against its limit. Results reflect the system's sampling points, not the plumbing in any one home.
Is M and M Mountain View Subdivision Em2 water hard?
Hardness has not been reported for M and M Mountain View Subdivision Em2 in a reviewed Consumer Confidence Report yet. The softener sizing widget uses a labelled county default until a report is reviewed.
Is M and M Mountain View Subdivision Em2 water fluoridated?
No fluoride result in the last 36 months.
Where does M and M Mountain View Subdivision Em2 water come from?
M and M Mountain View Subdivision Em2 draws from 1 active well. Source and treatment details are listed above.
What filter fits M and M Mountain View Subdivision Em2 water?
For drinking water the matching engine ranks Aquasana OptimH2O Reverse Osmosis + Claryum first for this profile, based on certified reduction claims for the contaminants flagged above. See the filters section for the reasoning and alternatives.
Who to call
- System contact: SPENCER, JOHN, 208-468-5502
- DEQ Boise Regional Office, 1445 N Orchard St, Boise ID 83706, (208) 373-0550
- Southwest District Health (well testing, septic, local health questions)
Sources
Sample results as of 2026-08-19; inventory and violations from EPA SDWIS; page built 2026-09-14. 53 individual results reviewed.
More: Canyon County, Uranium, Nitrate (as N)
Numbers are the system's samples at its taps and wells, not yours. Lead and copper are 90th percentiles from sampled homes. Well pages are nearby-sample estimates. Health text restates EPA and DEQ. Methodology.