Shamrock Villa Water Association water quality
Met every federal limit. hardness not in the latest CCR.
ID3140108. Data through 2026-03-20. DEQ record.
What's in it
Nothing flagged. Every contaminant tested in the latest 36 months was not detected or below half its limit.
9 other contaminants tested, not detected or well below the limit
Copper 0.20ppm Gross Alpha 7.16pCi/L HFPO-DA (GenX) ND Lead ND Nitrate (as N) 4.00ppm PFHxS ND PFNA ND Radium 226 + 228 ND Uranium 9.0ppb
Filters that match
APEC ROES-50 Essence 5-Stage Reverse Osmosis
under sink ro · diy
Nothing in this water is flagged. This is a taste and general-purpose choice, not a fix.
Nothing in this water calls for whole-house treatment. A drinking-water filter covers the exposure that matters. Whole-house units here are optional, mainly for taste and chlorine.
Detections ranked by share of the limitevery Tier 1 detection, highest first
Bar length is the highest result in the last 36 months as a share of the federal limit (MCL, or action level for lead and copper). The dark tick marks the limit. Gross alpha is compared after subtracting uranium, as DEQ does for compliance.
Full contaminants reporthighest, latest, limit, trend, last sample
| Contaminant | Highest, 36 mo | Federal limit | Share of limit | Status | Trend | Last sample |
|---|---|---|---|---|---|---|
| Copper 90th percentile at home taps note | 0.20ppm | 1.30ppm AL | Detected | 2024-12-31 | ||
| Gross Alphanote | 7.16pCi/L | 15.0pCi/L MCL | Detected | 2025-10-07 | ||
| HFPO-DA (GenX) | ND | 10.0ppt MCL | Not detected | 2026-03-20 | ||
| Lead 90th percentile at home taps note | 0.0ppb | 15.0ppb AL | Not detected | 2024-12-31 | ||
| Nitrate (as N) | 4.00ppm latest 3.90ppm | 10.00ppm MCL | Detected | 2025-10-07 | ||
| PFHxS | ND | 10.0ppt MCL | Not detected | 2026-03-20 | ||
| PFNA | ND | 10.0ppt MCL | Not detected | 2024-12-12 | ||
| Radium 226 + 228 | ND | 5.00pCi/L MCL | Not detected | 2025-10-07 | ||
| Uranium | 9.0ppb | 30.0ppb MCL | Detected | 2025-10-07 |
- Copper: 90th percentile of samples taken at customer taps. Results depend on the home's plumbing.
- Gross Alpha: Compliance uses the running average of gross alpha minus uranium. Shown value is the highest lab result; the adjusted average is 1.13 pCi/L after subtracting 6.03 pCi/L for uranium.
- Lead: 90th percentile of samples taken at customer taps. Results depend on the home's plumbing.
ppb = parts per billion (µg/L), ppm = parts per million (mg/L), ppt = parts per trillion. ND = not detected above the lab's reporting limit. MCL = federal maximum contaminant level; AL = action level for lead and copper (90th percentile of home taps); aesthetic = secondary standard for taste, odor or staining, not health. Bars show the highest result in 36 months as a share of the limit.
6 other regulated contaminants tested
| Contaminant | 36 mo max | Limit | Status | Last sample |
|---|---|---|---|---|
| Atrazine | ND | 3.0ppb | Not detected | 2025-10-07 |
| Benzene | ND | 5.0ppb | Not detected | 2025-10-07 |
| 1,2-Dibromo-3-chloropropane | ND | 0.2ppb | Not detected | 2025-10-07 |
| Tetrachloroethylene | ND | 5.0ppb | Not detected | 2025-10-07 |
| Sodium | 34.50ppm | none | Detected | 2025-10-07 |
| Trichloroethylene | ND | 5.0ppb | Not detected | 2025-10-07 |
Hardness
Hardness is not reported in the latest CCR. Hardness not reported for this system; softener sizing uses a regional default of 11.7 gpg until a CCR value is reviewed.
Track recordno violations in the last ten years
✓ no violation recorded n monitoring or reporting only n includes a health-based violation ? outside the loaded record
Lead and copper at the tap90th percentile of sampled homes against the action level
90th percentile of samples taken at customer taps. Results depend on the home's plumbing. Results are from sampled homes in this system, not from your tap. Home plumbing can add lead and copper. First-draw samples run higher than flushed ones.
90th percentile of samples taken at customer taps. Results depend on the home's plumbing. Results are from sampled homes in this system, not from your tap. Home plumbing can add lead and copper. First-draw samples run higher than flushed ones.
Where the water comes from2 active wells
2 active wells, and 0 treatment points on record (SDWIS counts each chlorination or filtration point as a treatment plant).
WELL #1 BACK UP WELL: Susceptibility: ioc high, voc moderate, soc high, microbial moderate.
Source water assessment susceptibility: final map[IOC:High Microbials:Moderate SOC:High VOC:Moderate]; hydrologic sensitivity H; pci land use map[IOC:M Microbials:M SOC:M VOC:M]; system construction M;
Source names (2)
WELL #1 BACK UP WELL, WELL #2
Every match, by categorytop three per category
We may earn a commission if you buy through these links. Rankings come from the matching engine (certification + flagged contaminants + annual cost), not from who pays more. How we earn money. As an Amazon Associate we earn from qualifying purchases. Prices are not shown; Amazon sets them on its site.
Drinking water
Under sink, pitcher, or faucet. Treats the water you drink and cook with.
APEC ROES-50 Essence 5-Stage Reverse Osmosis
Manufacturer-reported reduction for uranium, nitrate, and gross alpha. Not NSF-certified for uranium, nitrate, and gross alpha.
Plumber recommended if you are not comfortable with a drain saddle and a tank. Not a whole-house solution.
Aquasana OptimH2O Reverse Osmosis + Claryum
Certified for nitrate (NSF/ANSI 58); manufacturer-reported for uranium and gross alpha.
Plumber recommended if you are not comfortable with a drain saddle and a tank. Not a whole-house solution.
iSpring RCC7AK 6-Stage Alkaline Reverse Osmosis
Manufacturer-reported reduction for uranium, nitrate, and gross alpha. Not NSF-certified for uranium, nitrate, and gross alpha.
Plumber recommended if you are not comfortable with a drain saddle and a tank. Not a whole-house solution.
Whole house
Installed where water enters the house. For fixtures, laundry and showers.
Nothing in this water calls for whole-house treatment. A drinking-water filter covers the exposure that matters. Whole-house units here are optional, mainly for taste and chlorine.
Sprite High Output 2 Universal Shower Filter with 3-Setting Shower Head (HO2-WH-M)
No certified coverage for the flagged contaminants.
DIY. No plumbing.
Culligan WSH-C125 Wall-Mount Shower Filter
No certified coverage for the flagged contaminants.
DIY. No plumbing.
Culligan ISH-100 Inline Shower Filter
No certified coverage for the flagged contaminants.
DIY. No plumbing.
Softener or conditioner
Worth it at 7 grains per gallon or more.
Aquasure Serene Lite 650K Salt-Free Water Conditioner with Triple Purpose Pre-Filter
No certified coverage for the flagged contaminants.
Plumber recommended if you are not comfortable with this install.
Whirlpool WHES30E 30,000 Grain Water Softener
No certified coverage for the flagged contaminants.
DIY if you are comfortable with this install.
Whirlpool WHES40E 40,000 Grain Water Softener
No certified coverage for the flagged contaminants.
DIY if you are comfortable with this install.
Questions about Shamrock Villa Water Association
Is Shamrock Villa Water Association tap water safe to drink?
In the last 36 months of Idaho DEQ results, Shamrock Villa Water Association had no contaminant above a federal limit and EPA records no open health-based violation. Results reflect the system's sampling points, not the plumbing in any one home.
Is Shamrock Villa Water Association water hard?
Hardness has not been reported for Shamrock Villa Water Association in a reviewed Consumer Confidence Report yet. The softener sizing widget uses a labelled county default until a report is reviewed.
Is Shamrock Villa Water Association water fluoridated?
No fluoride result in the last 36 months.
Where does Shamrock Villa Water Association water come from?
Shamrock Villa Water Association draws from 2 active wells. Source and treatment details are listed above.
What filter fits Shamrock Villa Water Association water?
For drinking water the matching engine ranks APEC ROES-50 Essence 5-Stage Reverse Osmosis first for this profile, based on certified reduction claims for the contaminants flagged above. See the filters section for the reasoning and alternatives.
Who to call
- System contact: WALKER, KATHLEEN, 208-571-0577
- DEQ Boise Regional Office, 1445 N Orchard St, Boise ID 83706, (208) 373-0550
- Southwest District Health (well testing, septic, local health questions)
Sources
Sample results as of 2026-03-20; inventory and violations from EPA SDWIS; page built 2026-09-14. 37 individual results reviewed.
More: Canyon County