Tap and WellTreasure Valley water, from the public record

Capitol Water Corp. water quality

Met every federal limit. 7 contaminants at half a limit or higher. hardness not in the latest CCR.

ID4010022. Data through 2026-07-14. DEQ record.

What's in it

PFNA

Elevated
28.7ppt of 10.0ppt federal limit

Aquasana OptimH2O Reverse Osmosis + Claryum: manufacturer-reported, not certified.

PFOS

Elevated
7.1ppt of 4.0ppt federal limit

Aquasana OptimH2O Reverse Osmosis + Claryum is certified to reduce it.

PFOA

Elevated
5.7ppt of 4.0ppt federal limit

Aquasana OptimH2O Reverse Osmosis + Claryum is certified to reduce it.

Uranium

Elevated
18.5ppb of 30.0ppb federal limit

Aquasana OptimH2O Reverse Osmosis + Claryum: manufacturer-reported, not certified.

PFHxS

Elevated
4.5ppt of 10.0ppt federal limit

Aquasana OptimH2O Reverse Osmosis + Claryum: manufacturer-reported, not certified.

Arsenic

Elevated
3.1ppb of 10.0ppb federal limit

Aquasana OptimH2O Reverse Osmosis + Claryum is certified to reduce it.

PFBS

Elevated
3.9ppt

Aquasana OptimH2O Reverse Osmosis + Claryum: manufacturer-reported, not certified.

5 other contaminants tested, not detected or well below the limit

Gross Alpha 37.9pCi/L HFPO-DA (GenX) ND Nitrate (as N) ND Radium 226 + 228 ND Total Trihalomethanes ND

Filters that match

Start with this

Aquasana OptimH2O Reverse Osmosis + Claryum

under sink ro · diy

  • Arsenicremoves it, NSF or WQA certified
  • PFBSremoves it, per manufacturer testing
  • PFHxSremoves it, per manufacturer testing
  • PFNAremoves it, per manufacturer testing
  • PFOAremoves it, NSF or WQA certified
  • PFOSremoves it, NSF or WQA certified
  • Uraniumremoves it, per manufacturer testing
Whole house

Nothing in this water calls for whole-house treatment. A drinking-water filter covers the exposure that matters. Whole-house units here are optional, mainly for taste and chlorine.

Detections ranked by share of the limitevery Tier 1 detection, highest first
28.7ppt of 10.0ppt
lab result 51.0ppt
2.9x
Elevated avg
7.1ppt of 4.0ppt
lab result 9.8ppt
1.8x
Elevated avg
5.7ppt of 4.0ppt
1.4x
Elevated avg
18.5ppb of 30.0ppb
lab result 32.0ppb
62%
Elevated avg
4.5ppt of 10.0ppt
lab result 5.1ppt
45%
Elevated avg
4.10ppm of 10.00ppm
41%
Detected
3.1ppb of 10.0ppb
lab result 3.5ppb
31%
Elevated avg
0.00pCi/L of 15.0pCi/L
lab result 37.9pCi/L
0%
Not detected avg

Bar length is the highest result in the last 36 months as a share of the federal limit (MCL, or action level for lead and copper). The dark tick marks the limit. Gross alpha is compared after subtracting uranium, as DEQ does for compliance.

Aesthetic and unregulated

Taste, odor, staining or scale, not health limits. Bars use the EPA secondary standard where one exists.

no standard
3.9ppt
Elevated
Full contaminants reporthighest, latest, limit, trend, last sample
ContaminantHighest, 36 moFederal limitShare of limitStatusTrendLast sample
Arsenic3.5ppb10.0ppb MCL31%Elevated2025-08-14
Gross Alphanote37.9pCi/L
latest 25.0pCi/L
15.0pCi/L MCL0%Not detected2026-07-14
HFPO-DA (GenX)ND10.0ppt MCLNDNot detected2024-10-08 EPA study
Nitrate (as N)4.10ppm
latest ND
10.00ppm MCL41%Detected2026-07-14
PFBS3.9ppt
latest ND
noneno federal limitElevated2024-10-08 EPA study
PFHxS5.1ppt
latest ND
10.0ppt MCL45%Elevated2024-10-08 EPA study
PFNAnote51.0ppt
latest ND
10.0ppt MCL2.9xElevated2024-10-08 EPA study
PFOAnote5.7ppt
latest ND
4.0ppt MCL1.4xElevated2024-10-08 EPA study
PFOSnote9.8ppt
latest ND
4.0ppt MCL1.8xElevated2024-10-08 EPA study
Radium 226 + 228ND5.00pCi/L MCLNDNot detected2025-11-13
Total TrihalomethanesND80.0ppb MCLNDNot detected2026-07-14
Uranium32.0ppb
latest 5.0ppb
30.0ppb MCL62%Elevated2026-07-14
  • Gross Alpha: Compliance uses the running average of gross alpha minus uranium. Shown value is the highest lab result; the adjusted average is 0.0 pCi/L after subtracting 12.39 pCi/L for uranium.
  • PFNA: Detected in EPA's UCMR 5 monitoring study at or above the 2024 MCL. Study samples are not compliance monitoring; compliance sampling under the PFAS rule begins in 2027 and is judged on a running annual average.
  • PFOA: Detected in EPA's UCMR 5 monitoring study at or above the 2024 MCL. Study samples are not compliance monitoring; compliance sampling under the PFAS rule begins in 2027 and is judged on a running annual average.
  • PFOS: Detected in EPA's UCMR 5 monitoring study at or above the 2024 MCL. Study samples are not compliance monitoring; compliance sampling under the PFAS rule begins in 2027 and is judged on a running annual average.

ppb = parts per billion (µg/L), ppm = parts per million (mg/L), ppt = parts per trillion. ND = not detected above the lab's reporting limit. MCL = federal maximum contaminant level; AL = action level for lead and copper (90th percentile of home taps); aesthetic = secondary standard for taste, odor or staining, not health. Bars show the highest result in 36 months as a share of the limit.

7 other regulated contaminants tested
Contaminant36 mo maxLimitStatusLast sample
AtrazineND3.0ppbNot detected2025-11-13
BenzeneND5.0ppbNot detected2026-07-14
1,2-Dibromo-3-chloropropaneND0.2ppbNot detected2025-11-13
Lithium19.0ppbnoneDetected2023-12-06
TetrachloroethyleneND5.0ppbNot detected2026-07-14
Sodium52.60ppmnoneDetected2025-11-13
Trichloroethylene2.1ppb5.0ppbDetected2026-07-14

Hardness

Hardness is not reported in the latest CCR. Hardness not reported for this system; softener sizing uses a regional default of 11.7 gpg until a CCR value is reviewed.

See also Boise City water hardness.

Track record126 violations on record, 3 health-based
1 2017
2018
1 2019
2020
2021
2 2022
115 2023
2 2024
5 2025
2026

no violation recorded n monitoring or reporting only n includes a health-based violation ? outside the loaded record

Health-based violations

PeriodWhat happenedContaminantRuleStatus
2025-04-01 to 2025-06-30Maximum contaminant level exceeded (Single sample MCL exceeded)UraniumRadionuclidesresolved
2025-01-01 to 2025-03-31Maximum contaminant level exceeded (Single sample MCL exceeded)UraniumRadionuclidesresolved
2024-10-17Treatment technique not met (Level 2 assessment, treatment technique (RTCR))n/aLead and Copper Rule Revisionsresolved 2024-11-15
Monitoring and reporting violations (123)

A required sample or report was late or missing. These do not mean a contaminant was found, but a system that skips monitoring has gaps in its record.

YearRuleCountDetail
2025Public Notification Rule2 (1 open)Public notice rule linked to violation
2025Nitrates1Routine monitoring, major · Nitrate (as N)
2024Lead and Copper Rule Revisions1
2023Synthetic Organic Chemicals115Routine monitoring, major · 1,2-Dibromo-3-chloropropane, Atrazine
2022Radionuclides2Routine monitoring, major · Uranium
2019Revised Total Coliform Rule1Monitoring, routine (RTCR)
2017Lead and Copper Rule1Lead service line replacement (LCR)
Lead and copper at the tap90th percentile of sampled homes against the action level

No lead and copper tap sampling summary in the window we reviewed.

Where the water comes from5 active wells

5 active wells, and 4 treatment points on record (SDWIS counts each chlorination or filtration point as a treatment plant).

WELL #4: Susceptibility: ioc high (auto), voc high (auto), soc high (auto), microbial high (auto).

Source water assessment susceptibility: final map[IOC:Auto High Microbials:Auto High SOC:Auto High VOC:Auto High]; hydrologic sensitivity M; pci land use map[IOC:M Microbials:M SOC:M VOC:M]; system construction M;

Source names (5)

WELL #3, WELL #4, WELL #5 (NEW), WELL #6 BACK UP WELL, WELL #7

Every match, by categorytop three per category

We may earn a commission if you buy through these links. Rankings come from the matching engine (certification + flagged contaminants + annual cost), not from who pays more. How we earn money. As an Amazon Associate we earn from qualifying purchases. Prices are not shown; Amazon sets them on its site.

Drinking water

Under sink, pitcher, or faucet. Treats the water you drink and cook with.

Ranked first for this water under sink ro · DIY

Aquasana OptimH2O Reverse Osmosis + Claryum

Certified for arsenic, PFOA, and PFOS (NSF/ANSI 58, pentavalent); manufacturer-reported for uranium, PFHxS, and PFNA.

Plumber recommended if you are not comfortable with a drain saddle and a tank. Not a whole-house solution.

Certified forArsenic, Nitrate (as N), PFOA, PFOS and 1 more
Manufacturer-reported, not certifiedUranium, PFHxS, PFNA, PFBS
Also fits under sink ro · DIY

Waterdrop G3P800 Tankless Reverse Osmosis with UV

Certified for PFOA and PFOS (NSF/ANSI 58); manufacturer-reported for arsenic, uranium, and PFHxS.

Plumber recommended if you are not comfortable with a drain saddle and a tank. Not a whole-house solution.

Certified forPFOA, PFOS
Manufacturer-reported, not certifiedArsenic, Uranium, Nitrate (as N), PFHxS and 2 more

Whole house

Installed where water enters the house. For fixtures, laundry and showers.

Nothing in this water calls for whole-house treatment. A drinking-water filter covers the exposure that matters. Whole-house units here are optional, mainly for taste and chlorine.

Softener or conditioner

Worth it at 7 grains per gallon or more.

Questions about Capitol Water Corp.

Is Capitol Water Corp. tap water safe to drink?

Capitol Water Corp. met every federal limit in the last 36 months, with no open health-based violation. 7 contaminants were at half the limit or higher: Arsenic, PFBS, PFHxS, PFNA, PFOA, PFOS and Uranium. The results table shows each value against its limit. Results reflect the system's sampling points, not the plumbing in any one home.

Is Capitol Water Corp. water hard?

Hardness has not been reported for Capitol Water Corp. in a reviewed Consumer Confidence Report yet. The softener sizing widget uses a labelled county default until a report is reviewed.

Is Capitol Water Corp. water fluoridated?

No fluoride result in the last 36 months.

Where does Capitol Water Corp. water come from?

Capitol Water Corp. draws from 5 active wells with 4 treatment plants on record. Source and treatment details are listed above.

What filter fits Capitol Water Corp. water?

For drinking water the matching engine ranks Aquasana OptimH2O Reverse Osmosis + Claryum first for this profile, based on certified reduction claims for the contaminants flagged above. See the filters section for the reasoning and alternatives.

Who to call

  • System contact: PRICE, ROBERT H, 208-375-0931
  • DEQ Boise Regional Office, 1445 N Orchard St, Boise ID 83706, (208) 373-0550
  • Central District Health (well testing, septic, local health questions)

Sources

Sample results as of 2026-07-14; inventory and violations from EPA SDWIS; page built 2026-09-14. 198 individual results reviewed.

More: Boise City water, Ada County, Arsenic, Uranium, PFOA, PFOS, PFHxS, PFNA, PFBS

Numbers are the system's samples at its taps and wells, not yours. Lead and copper are 90th percentiles from sampled homes. Well pages are nearby-sample estimates. Health text restates EPA and DEQ. Methodology.