Tap and WellTreasure Valley water, from the public record

Linda Vista Mobile Home Park water quality

Met every federal limit. 2 contaminants at half a limit or higher. hardness not in the latest CCR.

ID4010088. Data through 2026-07-14. DEQ record.

What's in it

PFHxS

Elevated
5.8ppt of 10.0ppt federal limit

PUR Basic Vertical Faucet Mount Filter System is certified to reduce it.

4.8ppt of 10.0ppt federal limit

PUR Basic Vertical Faucet Mount Filter System is certified to reduce it.

4 other contaminants tested, not detected or well below the limit

Gross Alpha 4.13pCi/L Nitrate (as N) 3.70ppm Radium 226 + 228 ND Uranium 14.0ppb

Filters that match

Start with this

PUR Basic Vertical Faucet Mount Filter System

faucet mount · diy

  • HFPO-DA (GenX)removes it, NSF or WQA certified
  • PFHxSremoves it, NSF or WQA certified
Whole house

Nothing in this water calls for whole-house treatment. A drinking-water filter covers the exposure that matters. Whole-house units here are optional, mainly for taste and chlorine.

Detections ranked by share of the limitevery Tier 1 detection, highest first
5.8ppt of 10.0ppt
lab result 6.3ppt
58%
Elevated avg
4.8ppt of 10.0ppt
lab result 4.9ppt
48%
Elevated avg
14.0ppb of 30.0ppb
47%
Detected avg
3.70ppm of 10.00ppm
37%
Detected
0.00pCi/L of 15.0pCi/L
lab result 4.13pCi/L
0%
Not detected avg

Bar length is the highest result in the last 36 months as a share of the federal limit (MCL, or action level for lead and copper). The dark tick marks the limit. Gross alpha is compared after subtracting uranium, as DEQ does for compliance.

Full contaminants reporthighest, latest, limit, trend, last sample
ContaminantHighest, 36 moFederal limitShare of limitStatusTrendLast sample
Gross Alphanote4.13pCi/L15.0pCi/L MCL0%Not detected2025-04-08
HFPO-DA (GenX)4.9ppt10.0ppt MCL48%Elevated2026-07-14
Nitrate (as N)3.70ppm10.00ppm MCL37%Detected2026-03-10
PFHxS6.3ppt
latest 5.3ppt
10.0ppt MCL58%Elevated2026-07-14
Radium 226 + 228ND5.00pCi/L MCLNDNot detected2025-04-08
Uranium14.0ppb30.0ppb MCL47%Detected2025-04-08
  • Gross Alpha: Compliance uses the running average of gross alpha minus uranium. Shown value is the highest lab result; the adjusted average is 0.0 pCi/L after subtracting 9.38 pCi/L for uranium.

ppb = parts per billion (µg/L), ppm = parts per million (mg/L), ppt = parts per trillion. ND = not detected above the lab's reporting limit. MCL = federal maximum contaminant level; AL = action level for lead and copper (90th percentile of home taps); aesthetic = secondary standard for taste, odor or staining, not health. Bars show the highest result in 36 months as a share of the limit.

6 other regulated contaminants tested
Contaminant36 mo maxLimitStatusLast sample
AtrazineND3.0ppbNot detected2025-04-08
BenzeneND5.0ppbNot detected2025-04-08
1,2-Dibromo-3-chloropropaneND0.2ppbNot detected2025-04-08
TetrachloroethyleneND5.0ppbNot detected2025-04-08
Sodium46.30ppmnoneDetected2025-04-08
TrichloroethyleneND5.0ppbNot detected2025-04-08

Hardness

Hardness is not reported in the latest CCR. Hardness not reported for this system; softener sizing uses a regional default of 11.7 gpg until a CCR value is reviewed.

See also Boise City water hardness.

Track record4 violations on record, 0 health-based
1 2017
2018
1 2019
2020
2021
2022
2023
2024
2025
2026

no violation recorded n monitoring or reporting only n includes a health-based violation ? outside the loaded record

No health-based violations (MCL, treatment technique, or disinfectant level) in the last ten years.

Monitoring and reporting violations (4)

A required sample or report was late or missing. These do not mean a contaminant was found, but a system that skips monitoring has gaps in its record.

YearRuleCountDetail
2019Ground Water Rule1Monitoring, routine minor · E. coli
2017Stage 1 Disinfectants and Disinfection Byproducts Rule1Monitoring and reporting (DBP) · Chlorine (residual)
2014Ground Water Rule1 (1 open)
2013Public Notification Rule1 (1 open)Public notice rule linked to violation
Lead and copper at the tap90th percentile of sampled homes against the action level

No lead and copper tap sampling summary in the window we reviewed.

Where the water comes from1 active wells

1 active well, and 0 treatment points on record (SDWIS counts each chlorination or filtration point as a treatment plant).

WELL #1: Susceptibility: ioc high (auto), voc high (auto), soc high (auto), microbial moderate.

Source water assessment susceptibility: final map[IOC:Auto High Microbials:Moderate SOC:Auto High VOC:Auto High]; hydrologic sensitivity M; pci land use map[IOC:M Microbials:M SOC:M VOC:M]; system construction H;

Source names (1)

WELL #1

Every match, by categorytop three per category

We may earn a commission if you buy through these links. Rankings come from the matching engine (certification + flagged contaminants + annual cost), not from who pays more. How we earn money. As an Amazon Associate we earn from qualifying purchases. Prices are not shown; Amazon sets them on its site.

Drinking water

Under sink, pitcher, or faucet. Treats the water you drink and cook with.

Also fits under sink ro · DIY

APEC ROES-50 Essence 5-Stage Reverse Osmosis

Manufacturer-reported reduction for PFHxS, HFPO-DA, and uranium. Not NSF-certified for PFHxS, HFPO-DA, and uranium.

Plumber recommended if you are not comfortable with a drain saddle and a tank. Not a whole-house solution.

Manufacturer-reported, not certifiedUranium, Nitrate (as N), PFHxS, HFPO-DA (GenX) and 1 more

Whole house

Installed where water enters the house. For fixtures, laundry and showers.

Nothing in this water calls for whole-house treatment. A drinking-water filter covers the exposure that matters. Whole-house units here are optional, mainly for taste and chlorine.

Softener or conditioner

Worth it at 7 grains per gallon or more.

Questions about Linda Vista Mobile Home Park

Is Linda Vista Mobile Home Park tap water safe to drink?

Linda Vista Mobile Home Park met every federal limit in the last 36 months, with no open health-based violation. 2 contaminants were at half the limit or higher: HFPO-DA (GenX) and PFHxS. The results table shows each value against its limit. Results reflect the system's sampling points, not the plumbing in any one home.

Is Linda Vista Mobile Home Park water hard?

Hardness has not been reported for Linda Vista Mobile Home Park in a reviewed Consumer Confidence Report yet. The softener sizing widget uses a labelled county default until a report is reviewed.

Is Linda Vista Mobile Home Park water fluoridated?

No fluoride result in the last 36 months.

Where does Linda Vista Mobile Home Park water come from?

Linda Vista Mobile Home Park draws from 1 active well. Source and treatment details are listed above.

What filter fits Linda Vista Mobile Home Park water?

For drinking water the matching engine ranks PUR Basic Vertical Faucet Mount Filter System first for this profile, based on certified reduction claims for the contaminants flagged above. See the filters section for the reasoning and alternatives.

Who to call

  • System contact: WARE, JOSHUA, 208-407-1985
  • DEQ Boise Regional Office, 1445 N Orchard St, Boise ID 83706, (208) 373-0550
  • Central District Health (well testing, septic, local health questions)

Sources

Sample results as of 2026-07-14; inventory and violations from EPA SDWIS; page built 2026-09-14. 18 individual results reviewed.

More: Boise City water, Ada County, PFHxS, HFPO-DA (GenX)

Numbers are the system's samples at its taps and wells, not yours. Lead and copper are 90th percentiles from sampled homes. Well pages are nearby-sample estimates. Health text restates EPA and DEQ. Methodology.